Page last updated: 03/17/2023
DYS635 Variants
To contribute to this table, click here.
Allele Designation |
Allele Size (bp) |
Instrument |
Amp Kit* |
Contributor |
Verification/Conformation Method(s) |
Notes |
Frequency |
17 | 234.0 | ABI 310 | Y filer | George Schiro, Acadiana Criminalistics Laboratory | Reference sample, re-amplified to confirm | 1 | |
17 (<20) [2] | 234.13 | ABI 310 | YF | Cordelia Willis, Santa Clara County Crime Laboratory | Re-injection | reference | 1 |
17 (<20) [3] | 233.92 | ABI 3130xl | Yfiler | Phoenix PD Crime Lab | Re-amplified | Standard sample | 1 |
17 (<20) [4] | 233.68 | ABI 3130 | Yfiler | Anthony Birchfield, Oklahoma State Bureau of Investigation | Observed in questioned and reference samples and re-injection | 2 | |
17 [5] | 234.22 | ABI 3130xl | Yfiler | Pinellas County Forensic Laboratory | Reinjection | 1 | |
<20 [6] |
234.02 (vaginal swabs, amp 1), 234.03 (fingernail scrapings, amp 1), 234.12 (standard, amp 1), 233.94 (vaginal swabs, amp 2), 234.08 (fingernail scrapings, amp 2), 233.97 (standard, amp 2) |
ABI 310 | Yfiler | Kelly Lawrence, Northeastern Illinois Regional Crime Lab | Re-injected and re-amplified | Considered this a DYS635 peak because no peak observed in DYS635 range and a peak was observed in DYS439 | Just this case |
17 (<20) [7] | 233.96 | ABI 3130xl | Yfiler | Tayla L. Pinell, Louisiana State Police Crime Laboratory | Re-amplification | Unidentified remains (right phalanx bone); this specific Y-STR profile has three off-ladder marker range alleles; see also DYS456 and DYS448 | 1 |
17 [8] | 233.83 | ABI 3130xl | Yfiler | Domingos Biete Alfredo, Seccao de Biologia, Laboratorio Central de Criminalistica, Angola | Re-extracted and re-amplified with Prepfiler extraction method | Skin cells from the same case file | first observation |
18 (<20) | 238.03 | ABI 310 | YF | Cordelia Willis, Santa Clara County Crime Laboratory | Re-injection | reference | 1 |
18 [2] | 238.82 | ABI 3730 | Yfiler | DNA Forensic Division, Supreme Prosecutor's Office, South Korea | Re-amplified and re-analyzed with ABI 3130 | 1 in 6300 | |
21.3 | 253.33 | ABI 310 | YF | Cordelia Willis, Santa Clara County Crime Laboratory | Re-injection | reference | 1 |
27 | 273.98 | ABI 3500xl | Yfiler | Tal Ariel, Aviva Dell'Ariccia-Carmon and Aliza Raziel, Israel Police, DNA Database | Reamplified and reanalyzed | ||
27 [2] | 273.03 | ABI 3130 | Yfiler | Kristina Hoffman, WSP Marysville Crime Lab | Reinjection | Reference sample | 2 |
4 reported variants as of 11/09/15
Locus Duplication
Allele Designation |
Instrument |
Amp Kit* |
Contributor |
Verification/Conformation Method(s) |
Notes |
Frequency |
21, 22 | ABI 3130 | Yfiler | Cantagalli, VD; Gattás, GJF / Universidade de São Paulo, Brazil | Re-injection | 250.45 bp & 254.54 bp | 1 |
21, 22 [2] | ABI 3500XL | AmpFLSTR Yfiler PCR Amplification Kit, Thermo Fisher Scientific | IGNA (Saint Herblain, France) | one PCR reaction was performed. Haplotype was obtained from two forensic samples (from underwear). | Veriti Thermal Cycler, 24-capillary 3500xL Genetic Analyzer, Thermo Fisher Scientific | 1 |
1 reported as of 11/09/15
* Use the following abbreviations for amplification kit names:
- CO: Applied Biosystems COfiler
- PR: Applied Biosystems Profiler
- PS: Applied Biosystems Profiler Plus
- ID: Applied Biosystems Identifiler
- PP: Promega PowerPlex 16
- CV: Promega CTTV
- CA: Promega CTTA
- MP: Promega MonoPlex
- PPY: Promega PowerPlex Y
- YF: Applied Biosystems Yfiler
- Other: Please specify
Last Updated: 11/09/2015