Page last updated: 03/17/2023

DYS570 Variants


To contribute to this table, click here.

Allele Designation

Allele Size (bp)

Instrument

Amp Kit*

Contributor

Verification/Conformation Method(s)

Notes

Frequency
15.2414.11ABI 3500PowerPlex Fusion 6CKaylene Folks, Washington State Patrol Crime LaboratoryRe-injection2 questioned samples, one with a clear major and confirmed with re-injection
15.3~415ABI 3500xl PowerPlex Fusion 6CApril Perry, North Carolina State Crime Lab (NCSCL)samples re-injected1 questioned sample (mixture w/clear major) and 1 known sample (both confirmed with re-injection)
19.1134.91ABI 3500Todd Lindsey, Oklahoma State Bureau of InvestigationRe-setup with same result Questioned sample with partial Y-STR mixture; no extract remaining for re-amp
21.3 (OL)131.69 (PPY)ABI 3500XLPPY, YF PlusForensic DNA division, National Forensic Service, Ministry of the Interior and Safety, Republic of KoreaFirst re-amplified with PPY (allele size: 131.83) and concordance test with YF Plus (allele size: 145.26)The same variant allele was observed in the father and son.2 related individuals (2 in 1119)
27 (>25)459.12ABI 3500xlPowerPlex Fusion 6CMatthew Fisher, Washington State Patrol Crime LabRe-injection
               

1 reported variant as of 11/27/17

Locus Duplication

Allele Designation

Instrument

Amp Kit*

Contributor

Verification/Conformation Method(s)

Notes

Frequency
16, 17ABI 3500xl PowerPlex Fusion 6CMatthew Fisher, Washington State Patrol Crime Laboratory Re-amplified and re-analyzed1
17, 18ABI 3500PowerPlex Fusion 6C and Y ABI Filer PlusNatália Oliveira, Instituto de Genética Forense Eduardo Campos – Pernambuco – BrazilFirst amplified with PowerPlex Fusion 6C and re-amplified with ABI Y Filer PlusUnidentified remains - Allele Size: 126.19, 130.14 (ABI YF+), 333.74, 337.65 (PP F6C)First Observation
17, 18 [2]ABI 3500xl PowerPlex Fusion 6CMatthew Fisher, Washington State Patrol Crime LabRe-injectionconvicted offender - Allele Size: 420.38, 424.24
17, 18, 19ABI 3500XLPowerPlex Fusion 6CAbby Hernandez, Washington State Patrol Crime LabRe-Direct AmplificationConvicted Offender - Allele Size: 420.07, 424.01, 427.951
18, 19ABI 3500xlPowerPlex Fusion 6CAbby Hernandez, Washington State Patrol Crime LabRe-direct amplificationConvicted Offender - Allele Size: 423.44, 427.371
19, 20ABI 3500xlPowerPlex Fusion 6CMonica Price, WA State Patrol Crime LabRe-injectionConvicted offender
21, 22ABI 3500XLFusion 6CMatthew Fisher, Washington State Patrol Crime LabRe-direct amplificationAllele Size: 435.56, 439.53
             

1 reported as of 11/28/17

 

* Use the following abbreviations for amplification kit names:

 

RETURN TO VARIANT MENU

RETURN TO HOMEPAGE

Last Updated: 10/31/2012