Page last updated: 03/17/2023
D22S1045 Variants
To contribute to this table, click here.
Allele Designation |
Allele Size |
Instrument |
Amp Kit* |
Contributor |
Verification/Conformation Method(s) |
Notes |
Frequency |
8.1 | 89.89 (first injection); 89.85 (re-injection) | ABI 3500xl | GlobalFiler | Cynthia Cale, Houston Forensic Science Center | Re-injected. | Crime scene sample | 1 (first observation) |
11.1 | 447.98 | ABI 3500xl | PowerPlex Fusion 6C | Monica Price, WA State Patrol Crime Lab | Re-injection | Convicted offender | |
11.2 | 92.33 | ABI 3130xl | ESX 16 | Malin Sanga, Swedish National Laboratory of Forensic Science (SKL) | Re-amplified and re-electrophoresed | Reference sample | 1 (first observation) |
<12 | 99.44 or 99.45 | ABI 3500xl | GlobalFiler | Noora R. AlSnan, on behalf of Bahrain FSL Part of Arabian Gulf University PhD thesis | reamplified, re-electrophoresed, observed in different samples. | observed in 5 analyed samples so far. | |
13.2 | 98.09 | ABI 3130xl | ESX 16 | Malin Sanga, Swedish National Laboratory of Forensic Science (SKL) | Re-amplified and re-electrophoresed | Crime scene sample | 1 (first observation) |
13.2 | 103.35 | ABI 3500 | GlobalFiler | Vickie Beamer, Scottsdale PD Crime Lab | Re-injection | 1 | |
14.1 | 100.93 | ABI 3500xl | ESX 16 | Malin Sanga, Swedish National Forensic Centre (NFC) | Re-amplified and re-electrophoresed | Reference sample | 1 (first observation) |
15.2 | 104.30 | ABI 3130xl | ESX 16 | Malin Sanga, Swedish National Laboratory of Forensic Science (SKL) | Re-amplified and re-electrophoresed | Reference sample | 1 (first observation) |
15.2 [2] | 461.36 | ABI 3500xl | PowerPlex Fusion 6C | Abby Hernandez, Washington State Patrol Crime Lab | Re-Injection | Convicted Offender | 1 |
15.2 [3] | 455.33 | ABI 3500 | PowerPlex Fusion 5C | Tara Scott, Iowa DCI Crime Lab | Re-punched | Convicted Offender | |
21 | 477.36 | ABI 3500 | PowerPlex Fusion 6C | Amy Rathmann St. Louis Metropolitan Police Dept Crime Lab | Observed in Reference Standard and multiple samples from same case | 4 |
4 reported variants as of 07/08/2015
Tri-Allelic Patterns
Allele Designation |
Instrument |
Amp Kit* |
Contributor |
Verification/Conformation Method(s) |
Notes |
Frequency |
11, 15, 16 | ABI 3500 | PowerPlex ESI 16 |
Horolma Pamjav, Network of Forensic Science Institutes, Institute of Forensic Medicine, DNA Laboratory, Budapest, Hungary |
Observed in Hungarian population data | 1 in 21,473 | |
12, 13, 16 | ABI 3500xl | PowerPlex Fusion 6C | Monica Price, WA State Patrol Crime Lab | Re-direct amp | Type 1, Convicted offender | |
15, 16, 17 | ABI 3500xl | Applied Biosystems GlobalFiler | Dr. Praveesh Bhati, Dr. Anil K Singh, Dr. Pankaj Shrivastava | Confirmed by repeated PCR and re-electrophoresis | Allele Size:15(6283),16(3583),17(3184) | 1 |
3 reported tri-allelic pattern as of 11/28/2017
* Use the following abbreviations for amplification kit names:
- CO: Applied Biosystems COfiler
- PR: Applied Biosystems Profiler
- PS: Applied Biosystems Profiler Plus
- ID: Applied Biosystems Identifiler
- PP: Promega PowerPlex 16
- CV: Promega CTTV
- CA: Promega CTTA
- MP: Promega MonoPlex
- Other: Please specify
Last Updated: 07/08/2015